Skip to content
PSU Guide

DeepCool (GamerStorm) PN-M

1000/1200W

GoldATXATX 3.xFull modular2024
B-Published tier

2 known revisions of this model

Manufacturers revise a platform without changing the model name. Each row below is a distinct revision with its own rating.

Why this rating

Every criterion, its status, and the evidence behind it.

B-Published rating
D+Engine rating

Evidence

84%Well evidenced
PASS
10
WARN
0
FAIL
1
N/D
11
Rules v1.0.0

Ratings disagree by 4 steps

The engine rates this unit lower than the imported list, driven by the criteria listed below.

Architecture

  • PASS

    Resonant primary stage (LLC)weight 3

  • PASS

    Synchronous rectificationweight 2

  • PASS

    Independent DC-DC converters for +5V and +3.3Vweight 3

  • N/D

    PFC type is not documented; APFC assumed only when statedweight 2

Standards

  • PASS

    Declares ATX 3.x complianceweight 2

  • PASS

    Full-range input (~100-240 VAC)weight 2

Efficiency

  • PASS

    Gold class efficiencyweight 2

Components

  • N/D

    Capacitor temperature rating is not documentedweight 2

  • N/D

    Fan bearing type is not documentedweight 1.5

Protections

  • N/D

    Protection set has not been verified independentlyweight 3

  • N/D

    OCP declaration has not been verifiedweight 2

  • N/D

    OTP declaration has not been verifiedweight 1.5

  • FAIL

    Protection trip points are set poorly (OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.)weight 2

    OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.(editorial note)

Electrical performance

  • N/D

    No qualitative electrical assessment on recordweight 3

  • N/D

    No ripple measurement on recordweight 3

  • N/D

    No voltage regulation measurement on recordweight 2

  • N/D

    No transient response measurement on recordweight 2

Evidence

  • PASS

    Built by CWTweight 1.5

  • PASS

    Platform CSZ costdownweight 1.5

  • PASS

    Independent testing on record (OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.)weight 2

    OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.(editorial note)

Warranty and support

  • N/D

    Warranty length is not documentedweight 1.5

Safety

  • PASS

    No safety incidents or false claims on recordweight 3

How the tier was reached

  1. MISSED

    Tier A - reference classspec 12.9

    • Protection trip points: Protection trip points are set poorly (OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.)
    • Too many failed criteria for this tier (1)
  2. MISSED

    Tier B - strong mainstreamspec 12.10

    • Protection trip points: Protection trip points are set poorly (OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.)
    • Too many failed criteria for this tier (1)
  3. MISSED

    Tier C - adequatespec 12.11

    • Protection trip points: Protection trip points are set poorly (OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing.)
    • Too many failed criteria for this tier (1)
  4. MET

    Tier D - basicspec 12.12

  • Weighted pass ratio 92% with no warnings

Missing evidence

These criteria could not be resolved. They lower the confidence index rather than count against the unit.

  • Active power factor correction
  • Electrolytic capacitor temperature rating
  • Fan bearing type
  • Protection coverage
  • Over-current protection declared
  • Over-temperature protection declared
  • Measured electrical behaviour
  • +12V ripple
  • Voltage regulation
  • +12V transient response
  • Manufacturer warranty

Specification

Values carry the source they came from; unknowns stay unknown.

Capacities
1000 W1200 W
Form factor
ATX
ATX generation
ATX 3.x
Efficiency class
Gold
AC input
Full range (~100–240 V)
Cable modularity
Full
Introduced
2024

Electrical architecture

What is actually inside, when it is known.

Primary stage
LLC
Secondary rectification
SR
Minor rail regulation
DC-DC
Built by
CWT
Platform
CSZ costdown

Reviewer notes

Free text from the source, used by the engine as signals.

OCP is set way too high on the minor rails, which led to failure of the unit during Aris testing. Detier to B- unless verified fixed

  • Protection trip points criticisednoconfidence 60%
  • Independent laboratory testing referencedyesconfidence 60%

Where this data comes from

Each field records which source supplied it and how sure we are.

FieldSourceConfidenceCaptured
oemPSU Tier List (seed workbook)trust 7070%workbook import
intro_yearPSU Tier List (seed workbook)trust 7070%workbook import
modularityPSU Tier List (seed workbook)trust 7070%workbook import
atx_versionPSU Tier List (seed workbook)trust 7070%workbook import
form_factorPSU Tier List (seed workbook)trust 7070%workbook import
input_rangePSU Tier List (seed workbook)trust 7070%workbook import
platformPSU Tier List (seed workbook)trust 7070%workbook import
editorial_tierPSU Tier List (seed workbook)trust 7070%workbook import
efficiency_classPSU Tier List (seed workbook)trust 7070%workbook import
primary_topologyPSU Tier List (seed workbook)trust 7070%workbook import
minor_rail_regulationPSU Tier List (seed workbook)trust 7070%workbook import
secondary_rectificationPSU Tier List (seed workbook)trust 7070%workbook import

Primary source: PSU Tier List (seed workbook) (row 482). Community-maintained tier list imported as the seed data set. Ratings from this source are shown as the published tier; the Tier Engine computes its own rating separately.

Built on the same platform

Different badge, same electrical design.

750/850W

no price yet

GoldATXATX 2.xDC-DC
Built by
CWT
Platform
GPX ATX 3.0
Introduced
2023
Engine rating
D(74%)