Skip to content
PSU Guide

Andyson E5+

300-500W

No certATXATX 2.xnon-modular230V only2017
FPublished tier

Why this rating

Every criterion, its status, and the evidence behind it.

FPublished rating
FEngine rating

Evidence

69%Limited lab data
PASS
3
WARN
1
FAIL
5
N/D
13
Rules v1.0.0

Critical failure

  • No active PFC - the unit cannot satisfy a modern ATX power supply role (Passive PFC - cannot meet modern ATX expectations (PPFC))

Architecture

  • FAIL

    Legacy primary topology (DF)weight 3

  • FAIL

    Passive (Schottky) rectificationweight 2

  • FAIL

    Group-regulated minor railsweight 3

  • FAIL

    Passive PFC - cannot meet modern ATX expectations (PPFC)weight 2

    PPFC(editorial note)

Standards

  • WARN

    ATX 2.x generation platformweight 2

  • FAIL

    Restricted 230V-only inputweight 2

Efficiency

  • N/D

    Efficiency class is not documentedweight 2

Components

  • N/D

    Capacitor temperature rating is not documentedweight 2

  • N/D

    Fan bearing type is not documentedweight 1.5

Protections

  • N/D

    Protection set has not been verified independentlyweight 3

  • N/D

    OCP declaration has not been verifiedweight 2

  • N/D

    OTP declaration has not been verifiedweight 1.5

  • N/D

    Protection trip points have not been measuredweight 2

Electrical performance

  • N/D

    No qualitative electrical assessment on recordweight 3

  • N/D

    No ripple measurement on recordweight 3

  • N/D

    No voltage regulation measurement on recordweight 2

  • N/D

    No transient response measurement on recordweight 2

Evidence

  • PASS

    Built by Andysonweight 1.5

  • PASS

    Platform E5+weight 1.5

  • N/D

    No independent laboratory report linked yetweight 2

Warranty and support

  • N/D

    Warranty length is not documentedweight 1.5

Safety

  • PASS

    No safety incidents or false claims on recordweight 3

How the tier was reached

  1. MET

    Critical failurespec 12.14

  • Tier F assigned by critical failure rules (spec 12.14)

Specification

Values carry the source they came from; unknowns stay unknown.

Capacities
300 W*350 W*400 W*430 W*450 W*500 W** inferred from a range
Form factor
ATX
ATX generation
ATX 2.x
Efficiency class
None
AC input
230V
Cable modularity
No
Introduced
2017

Electrical architecture

What is actually inside, when it is known.

Primary stage
DF
Secondary rectification
PR
Minor rail regulation
GR
Built by
Andyson
Platform
E5+

Reviewer notes

Free text from the source, used by the engine as signals.

PPFC

  • Passive PFC stated in the editorial notenoconfidence 60%

Where this data comes from

Each field records which source supplied it and how sure we are.

FieldSourceConfidenceCaptured
oemPSU Tier List (seed workbook)trust 7070%workbook import
intro_yearPSU Tier List (seed workbook)trust 7070%workbook import
modularityPSU Tier List (seed workbook)trust 7070%workbook import
atx_versionPSU Tier List (seed workbook)trust 7070%workbook import
form_factorPSU Tier List (seed workbook)trust 7070%workbook import
input_rangePSU Tier List (seed workbook)trust 7070%workbook import
platformPSU Tier List (seed workbook)trust 7070%workbook import
editorial_tierPSU Tier List (seed workbook)trust 7070%workbook import
efficiency_classPSU Tier List (seed workbook)trust 7070%workbook import
primary_topologyPSU Tier List (seed workbook)trust 7070%workbook import
minor_rail_regulationPSU Tier List (seed workbook)trust 7070%workbook import
secondary_rectificationPSU Tier List (seed workbook)trust 7070%workbook import

Primary source: PSU Tier List (seed workbook) (row 102). Community-maintained tier list imported as the seed data set. Ratings from this source are shown as the published tier; the Tier Engine computes its own rating separately.

Built on the same platform

Different badge, same electrical design.

Check this against my buildAdd to comparison