Skip to content
PSU Guide

Abko (Abkoncore) Coremax (CM) B (Bronze)

500W

BronzeATXATX 2.xnon-modular230V only2024
EPublished tier

Why this rating

Every criterion, its status, and the evidence behind it.

EPublished rating
EEngine rating

Evidence

63%Limited lab data
PASS
3
WARN
2
FAIL
5
N/D
12
Rules v1.0.0

Architecture

  • FAIL

    Legacy primary topology (DF)weight 3

  • FAIL

    Passive (Schottky) rectificationweight 2

  • PASS

    Independent DC-DC converters for +5V and +3.3Vweight 3

  • N/D

    PFC type is not documented; APFC assumed only when statedweight 2

Standards

  • WARN

    ATX 2.x generation platformweight 2

  • FAIL

    Restricted 230V-only inputweight 2

Efficiency

  • WARN

    Bronze class efficiencyweight 2

Components

  • N/D

    Capacitor temperature rating is not documentedweight 2

  • N/D

    Fan bearing type is not documentedweight 1.5

Protections

  • N/D

    Protection set has not been verified independentlyweight 3

  • N/D

    OCP declaration has not been verifiedweight 2

  • N/D

    OTP declaration has not been verifiedweight 1.5

  • FAIL

    Protection trip points are set poorly (5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.)weight 2

    5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.(editorial note)

Electrical performance

  • FAIL

    Electrical performance criticised: 5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.weight 3

    5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.(editorial note)

  • N/D

    No ripple measurement on recordweight 3

  • N/D

    No voltage regulation measurement on recordweight 2

  • N/D

    No transient response measurement on recordweight 2

Evidence

  • PASS

    Built by PREEweight 1.5

  • N/D

    Platform has not been identifiedweight 1.5

  • N/D

    No independent laboratory report linked yetweight 2

Warranty and support

  • N/D

    Warranty length is not documentedweight 1.5

Safety

  • PASS

    No safety incidents or false claims on recordweight 3

How the tier was reached

  1. MISSED

    Tier A - reference classspec 12.9

    • Primary conversion stage: Legacy primary topology (DF)
    • Secondary rectification: Passive (Schottky) rectification
    • Efficiency certification: Bronze class efficiency
    • AC input range: Restricted 230V-only input
    • Protection trip points: Protection trip points are set poorly (5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.)
    • Measured electrical behaviour: Electrical performance criticised: 5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.
    • Too many failed criteria for this tier (5)
  2. MISSED

    Tier B - strong mainstreamspec 12.10

    • Primary conversion stage: Legacy primary topology (DF)
    • Secondary rectification: Passive (Schottky) rectification
    • Protection trip points: Protection trip points are set poorly (5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.)
    • Measured electrical behaviour: Electrical performance criticised: 5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.
    • Too many failed criteria for this tier (4)
  3. MISSED

    Tier C - adequatespec 12.11

    • Protection trip points: Protection trip points are set poorly (5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.)
    • Measured electrical behaviour: Electrical performance criticised: 5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.
    • Too many failed criteria for this tier (2)
  4. MISSED

    Tier D - basicspec 12.12

    • Secondary rectification: Passive (Schottky) rectification
    • Measured electrical behaviour: Electrical performance criticised: 5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.
  • Insufficient evidence, unknown platform or unsatisfactory architecture (spec 12.13)
  • Modifiers do not apply to E and F

Missing evidence

These criteria could not be resolved. They lower the confidence index rather than count against the unit.

  • Active power factor correction
  • Electrolytic capacitor temperature rating
  • Fan bearing type
  • Protection coverage
  • Over-current protection declared
  • Over-temperature protection declared
  • +12V ripple
  • Voltage regulation
  • +12V transient response
  • Platform attribution
  • Independent laboratory evidence
  • Manufacturer warranty

Specification

Values carry the source they came from; unknowns stay unknown.

Capacities
500 W
Form factor
ATX
ATX generation
ATX 2.x
Efficiency class
Bronze
AC input
230V
Cable modularity
No
Introduced
2024

Electrical architecture

What is actually inside, when it is known.

Primary stage
DF
Secondary rectification
PR
Minor rail regulation
DC-DC
Built by
PREE
Platform
not documented

Reviewer notes

Free text from the source, used by the engine as signals.

5VSB has >60mV of ripple in crossloads and OCP is poorly tuned, with high ripple for all rails.

  • Electrical performance criticised by the reviewernoconfidence 60%
  • Protection trip points criticisednoconfidence 60%

Where this data comes from

Each field records which source supplied it and how sure we are.

FieldSourceConfidenceCaptured
oemPSU Tier List (seed workbook)trust 7070%workbook import
intro_yearPSU Tier List (seed workbook)trust 7070%workbook import
modularityPSU Tier List (seed workbook)trust 7070%workbook import
atx_versionPSU Tier List (seed workbook)trust 7070%workbook import
form_factorPSU Tier List (seed workbook)trust 7070%workbook import
input_rangePSU Tier List (seed workbook)trust 7070%workbook import
platformPSU Tier List (seed workbook)trust 7070%workbook import
editorial_tierPSU Tier List (seed workbook)trust 7070%workbook import
efficiency_classPSU Tier List (seed workbook)trust 7070%workbook import
primary_topologyPSU Tier List (seed workbook)trust 7070%workbook import
minor_rail_regulationPSU Tier List (seed workbook)trust 7070%workbook import
secondary_rectificationPSU Tier List (seed workbook)trust 7070%workbook import

Primary source: PSU Tier List (seed workbook) (row 27). Community-maintained tier list imported as the seed data set. Ratings from this source are shown as the published tier; the Tier Engine computes its own rating separately.

Check this against my buildAdd to comparison