1st Player ACK Standard
550/650/750W
Why this rating
Every criterion, its status, and the evidence behind it.
Evidence
- PASS
- 3
- WARN
- 1
- FAIL
- 7
- N/D
- 11
Ratings disagree by 4 steps
The engine rates this unit lower than the imported list, driven by the criteria listed below.
Architecture
- FAIL
Legacy primary topology (DF)weight 3
- FAIL
Passive (Schottky) rectificationweight 2
- FAIL
Group-regulated minor railsweight 3
- N/D
PFC type is not documented; APFC assumed only when statedweight 2
Standards
- WARN
ATX 2.x generation platformweight 2
- FAIL
Restricted 230V-only inputweight 2
Efficiency
- FAIL
No efficiency certification claimedweight 2
Components
- N/D
Capacitor temperature rating is not documentedweight 2
- N/D
Fan bearing type is not documentedweight 1.5
Protections
- N/D
Protection set has not been verified independentlyweight 3
- FAIL
OCP is not claimed on any rail (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)weight 2
OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.(editorial note)
- N/D
OTP declaration has not been verifiedweight 1.5
- FAIL
Protection trip points are set poorly (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)weight 2
OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.(editorial note)
Electrical performance
- N/D
No qualitative electrical assessment on recordweight 3
- N/D
No ripple measurement on recordweight 3
- N/D
No voltage regulation measurement on recordweight 2
- N/D
No transient response measurement on recordweight 2
Evidence
- PASS
Built by Hellyweight 1.5
- PASS
Platform ATX-0200weight 1.5
- N/D
No independent laboratory report linked yetweight 2
Warranty and support
- N/D
Warranty length is not documentedweight 1.5
Safety
- PASS
No safety incidents or false claims on recordweight 3
How the tier was reached
- MISSED
Tier A - reference classspec 12.9
- — Primary conversion stage: Legacy primary topology (DF)
- — Secondary rectification: Passive (Schottky) rectification
- — Minor rail regulation: Group-regulated minor rails
- — Efficiency certification: No efficiency certification claimed
- — AC input range: Restricted 230V-only input
- — Over-current protection declared: OCP is not claimed on any rail (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)
- — Protection trip points: Protection trip points are set poorly (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)
- — Too many failed criteria for this tier (7)
- MISSED
Tier B - strong mainstreamspec 12.10
- — Primary conversion stage: Legacy primary topology (DF)
- — Secondary rectification: Passive (Schottky) rectification
- — Minor rail regulation: Group-regulated minor rails
- — Efficiency certification: No efficiency certification claimed
- — Over-current protection declared: OCP is not claimed on any rail (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)
- — Protection trip points: Protection trip points are set poorly (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)
- — Too many failed criteria for this tier (6)
- MISSED
Tier C - adequatespec 12.11
- — Minor rail regulation: Group-regulated minor rails
- — Protection trip points: Protection trip points are set poorly (OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.)
- — Too many failed criteria for this tier (2)
- MISSED
Tier D - basicspec 12.12
- — Minor rail regulation: Group-regulated minor rails
- — Secondary rectification: Passive (Schottky) rectification
- — Efficiency certification: No efficiency certification claimed
- — Too many failed criteria for this tier (3)
- Insufficient evidence, unknown platform or unsatisfactory architecture (spec 12.13)
- Modifiers do not apply to E and F
Missing evidence
These criteria could not be resolved. They lower the confidence index rather than count against the unit.
- Active power factor correction
- Electrolytic capacitor temperature rating
- Fan bearing type
- Protection coverage
- Over-temperature protection declared
- Measured electrical behaviour
- +12V ripple
- Voltage regulation
- +12V transient response
- Independent laboratory evidence
- Manufacturer warranty
Specification
Values carry the source they came from; unknowns stay unknown.
- Capacities
- 550 W650 W750 W
- Form factor
- ATX
- ATX generation
- ATX 2.x
- Efficiency class
- White
- AC input
- 230V
- Cable modularity
- No
- Introduced
- 2025
Reviewer notes
Free text from the source, used by the engine as signals.
OCP is not claimed on any rail (although it most likely exists for the minor rails only), very low +12V line output relative to total capacity.
- OCP not claimed on any railnoconfidence 60%
- Protection trip points criticisednoconfidence 60%
Where this data comes from
Each field records which source supplied it and how sure we are.
| Field | Source | Confidence | Captured |
|---|---|---|---|
| oem | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| intro_year | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| modularity | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| atx_version | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| form_factor | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| input_range | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| platform | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| editorial_tier | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| efficiency_class | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| primary_topology | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| minor_rail_regulation | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
| secondary_rectification | PSU Tier List (seed workbook)trust 70 | 70% | workbook import |
Primary source: PSU Tier List (seed workbook) (row 6). Community-maintained tier list imported as the seed data set. Ratings from this source are shown as the published tier; the Tier Engine computes its own rating separately.
Built on the same platform
Different badge, same electrical design.
DeepCool (GamerStorm)
PF
350-650W
no price yet
Redragon
RGPS Bronze Non-Modular
500/600W
no price yet
Redragon
RGPS Bronze Full Modular
600W
no price yet
1st Player
Black Sir
500-600W
no price yet
1st Player
PRO
500-700W
no price yet
1st Player
FK
500-750W
no price yet